Furnace gas analyzer for reducing atmosphere furnace CPX Item No:CPX

Furnace gas analyzer for reducing atmosphere furnace CPXItem No:CPX

Features

 

● Fast response and optimal for control

 

● Easy sensor replacement

 

● Direct connection type, no sampling piping required

 

Place of use

 

Transformer furnace, carburizing furnace, continuous furnace, intermittent furnace, quenching furnace, annealing furnace, ferrite firing furnace

 

The CP-X oxygen partial pressure gauge is mounted on the furnace wall, and the sample gas is introduced into the analyzer by the pressure difference between the measured gas inlet and outlet. The oxygen gas partial pressure of the sample gas introduced is detected by a sensor.

 

Model

CP-X

Measurement principle

Zirconia concentration cell method

Measurement range

1 to 10-25 O2atm

Response time

 90% response 10s or less

Outer shape

About W130 × D300 × H120

Weight

About 4kg