TM-0013-SW is the display record system for a dust-explosion-proof type seismic monitoring system SW-52EX and standard seismic monitoring system SW-52ST. This display can be connected 3 systems, also can display and record the seismic information of 3 systems. It acquires waveform and can output after logical judgement (AND/OR/2 out of 3) against seismic alarm.
Features
SW-52ST/SW-52EX can calculate at real time modified mercalli seismic intensity scale(estimate value by PGA) and SI value, so called “velocity response spectrum”, which is one of the standards to express an earthquake's destructive power against structures by using built-in servo type accelerometer.
Features
Item | Specification |
---|---|
Number of connectable seismometer |
Maximum 3 |
Screen display | 7 inch ( 800 x 480 dot), Color LCD touch panel with TFT Earthquake monitor : current date and time, earthquake occurrence date and time, maximum value (intensity scale, acceleration, SI value), alarm output condition Recording data : log, earthquake history Setting : time, main body, seismometer system, print Maintenance : waveform data acquisition, test, memory card |
Alarm contact output | Photo-MOS relay, contact rating : 60 V- 2.5 A (for both AC / DC, peak value) Earthquake alarm : up to 7-steps, 1a contact (On alarm occurrence : close) Reset method : external input, internal timer (Seismometer setting), touch panel switch / FAULT alarm : 1a contact (At alarm occurrence: open) |
Interface (dedicated connector) |
Seismometer connection, alarm output, analog output, digital input |
Interface (others) | RJ-45 (LAN), USB2.0 (TypeA), SD memory card slot, power supply jack |
Clock | Accuracy : 20 ppm (daily error of 2 seconds) or better / Seismometer time management : synchronized with main unit time at calibration |
Mounting method | Wall hanging, panel / rack mount (storing cabinet) |
Operating temperature range |
0 – 40 °C |
Operating humidity range |
20 – 85 %RH (non-condensing) |
Power supply | 100 – 240 VAC |
Mass | Display unit : Approx. 2 kg / Including cabinet : Approx.8 kg |
Item | Specification | |||
---|---|---|---|---|
Detection method | Non-directional detection by acceleration with vector composition | |||
Built-in pickup | Force-balancing servo acceleration pickup, sensitivity : 2.04 mV / Gal, ±5 % (gravity acceleration standard) | |||
Acceleration measurement |
Measurement range |
0 to 5000 Gal (composite value of three component vectors) , NS and EW axes : ±3000 Gal, UD axis : +2000 to -3000 Gal |
||
Rated range | 0 to 3000 Gal (composite value of three component vectors), ±3 % FS (3000 Gal) | |||
Frequency range | 0.3 to 10 Hz (±10 %) | |||
Spectrum intensity measurement | Natural period 0.1 sec. /step by measured acceleration Real time calculation of velocity response spectrum by 25 pieces of 1 degree of freedom simulation filters |
|||
Measurement range |
0 to 5000 Kine (composite value of three component vectors) (Period 2 seconds, 5000 Gal, Dumping 2 %) |
|||
Rated range | 0 to 6000 Kine (composite value of three component vectors) ±3 %FS (600 Kine) (Period 1 second, 3000 Gal, Dumping 20 %) |
|||
Cycle range | 0.1 to 2.5 seconds (0.1 sec. step) | |||
Damping | 2 to 30 % (arbitrarily setting of 1 % stepping) | |||
Low-pass filter | 30 Hz (-3 dB), 4th order Butterworth filter | |||
A / D converter | 24 bit, 100 Hz sampling | |||
Data recording | History data : 50 cases+1 case (No.0 – 50) / Waveform data : 20 cases+1 case (No.0 – 20) / Saving format : Selected from latest priority and maximum priority *Top 21 cases of history data (No.0 – 20) are always correspond to waveform data *To acquire the recorded data, dedicated software is necessary |
|||
Analog output | DC4 – 20 mA x 2 pcs. (resistive load of 300 Ω or less), Switchable output data (acceleration / seismic intensity scale / spectrum intensity, according to the setting) Full scale:10 to 3000 Gal / Kine ±3 % full span (16 mA) (seismic intensity scale is fixed full scale, 1.6 mA step 10 step output) |
|||
Relay output | 1a contact (Photo-MOS relay) Contact rating : 40 V, 0.8 A (for both AC / DC, peak value) Output content : Select from earthquake alarm or FAULT |
|||
Digital output | Open collector output x 3 pcs. (D-GND common) Rated output : 30 V, 50 mA Output detail : select from seismic alarm / FAULT |
|||
Earthquake alarm | Output when it detects earthquake and exceeds the setting level OFF at normal time (relay non-excitation, transistor release ) / ON at alarm occurrence Output factor: select from acceleration / instrumental seismic intensity / SI value Output level : 0.1– 999.9(Gal / Kine / instrument seismic intensity)0.1 step, 0.0 means alarm action OFF Reset time: 1– 9999 sec., 1 sec. step 0 second means no automatic reset |
|||
Earthquake alarm reset |
Internal timer or digital input (need to set digital input) | |||
FAULT alarm | Hardware self-diagnosis, Output from abnormal detection of pickup test, pickup self-diagnosis and system power discontinuity. On at normal time (Relay excitation, transistor short circuit) / OFF at alarm occurrence |
|||
Hardware self-diagnosis |
Diagnosis detail : abnormal monitoring of internal power voltage/detection timing : normal time | |||
Pickup self diagnosis |
Diagnosis detail : abnormal monitoring of angular displacement detection mechanism / detection timing : 2 minutes after start and every 30 second cycle |
|||
Pickup test | Diagnosis detail : Abnormal diagnosis by servomechanism / detection timing :Schedule (Once in a month or everyday)Or digital input (digital input setting is necessary) Schedule setting : ON / OFF of schedule execution, execution once a month by setting of day, time, minute and second. (Everyday execution when the date is set to be “0”.) *Seismic monitoring is stop during pickup test. |
|||
Digital input | Open collector or non-voltage contact input × 1 pcs (D-GND common) / Open voltage : approx.13 V / input pulse width : more than 0.1 sec. / function switching method by communication setting : seismometer alarm reset, time correction, pickup test |
|||
Serial I / F | Collection of measured data, change in system setting, state monitoring, pickup test, digital input function switching Interface: RS-485 (2-wire half-duplex communication) / Communication speed: 115,200 bps/protocol:Modbus(RTU mode) |
|||
Clock | Accuracy : 20ppm (monthly error of 50 seconds or better) / Calibration: ±30 second correction by digital input (digital input setting is necessary) |
|||
Operational temperature range |
0 to +50 ゚C | |||
Operational humidity range |
10 to 100 %RH | |||
Power supply | 24 VDC ±10 %, ≦10 W | |||
Construction | SW-52ST | Dust proof, Flood prevention IP67 | SW-52EX | Explosion proof Ex db IIB+H2 T6 / Dust explosion-proof Ex tb III 120 ゚C Db |
Mounting method | Installation on the ground ( fixed by anchor) | |||
I / O cable | SW-52ST | For connection with a water-proof connector | SW-52EX | Cable ground (Internal terminal block connection) |
Mass | Approx. 2 kg | Approx. 5 kg | ||
Painted color | Metalic silver |