Use
Reflow furnace, ferrite baking furnace, other atmosphere management / combustion management applications
The SH-200 series sensor is a 2-cell limited current system that uses the current output of a controlled sensor.
This model contains the sensor, receiver and sampling parts in one unit.
Specification
Model |
SH-204-AW (Contact us for other models) |
Measurement principle |
Zirconia 2-cell pump system |
Measurement range |
0-100ppm-0-25% 4 arbitrary ranges can be |
Linearity |
±5%FS |
Repeatability |
± 1% FS |
Response time |
Response time 0-1000ppm or less: 60s or less 0-1000ppm or more: 30s or less (T90 response when switching calibration gas) |
Analog output |
4-20mA DC (fixed), 0-1, 0-5, 0-10V selectable |
Proofreading |
Air one-point calibration (standard gas required depending on measurement range) |
Mounting |
Panel cut, installed inside the device |
Power supply |
AC100-240V |
Outline |
About W252 × D210 × H151 |
weight |
About 5kg |