MC-8W-P Item No:MC-8W-P

MC-8W-PItem No:MC-8W-P

● Even in wastewater treatment facilities where the flow velocity tends to fluctuate, the indicated values are easy to stabilize and monitoring can be performed with confidence.
● Less susceptible to interfering substances such as hydrogen sulfide, enabling stable measurement

[Common features]
● Compact body (DIN96 [96mm square] size) anywhere
● Control mode can be selected from seven types of patterns by operating panel keys, subject to the set upper and lower limits.
Example) Gas replacement control, device operation control, signal generation control

Immersion type MC-8W-P (fluorescent sensor)

 

 

 

 

 

 

 

 

・ DO monitoring of wastewater treatment facilities (aeration tanks) (aerobic / anaerobic tanks, denitrification tanks, nitrification tanks)
・ DO monitoring of aquaculture ponds (sea areas)
・ Monitoring of water pollution of rivers, etc.

 

 

Product name / type

DO controller MC-8W-P

Measurement method

Optical (fluorescent) (JIS K0102: 2016)

Display method

LED digital display

Measurement range

0.00~20.00mg/L

accuracy

Linearity

0.00 to 8.00 mg / L: ± 0.1 mg / L (constant temperature)

8.01 to 20.00mg / L: ± 0.2mg / L (constant temperature)

Response speed (90% response)

Within 45 seconds (20 ℃)

Analog output

DC 4-20mA * 2 (Maximum load resistance 400Ω)

Range selection [0-20mg / L, 0-10mg / L, 0-1mg / L, 0-0.1mg / L]

Control output

Upper / lower limit 2 points no-voltage a contact output, contact capacity AC250V 2A Select from 7 types of control conditions with panel keys

With delay timer function to soften hunting

(Can be set from 0 to 9 seconds)

Control output setting range

0.00~20.00mg/L

Calibration method

One-touch calibration

Self-diagnosis function

Automatically diagnoses unstable / incorrect calibration and displays a message during calibration

Automatically diagnoses malfunctions and displays messages during measurement

Correction coefficient function

Correction of chloride ions, etc.

Time constant function

Averages and displays the measured values over the set time (Setting range is 1.0 to 10.0 seconds)

Operating temperature limit

DO controller: -5 to 50 ° C (no condensation)

Sensor cap and probe: 0 ~ 50 ℃ Automatic temperature compensation

cable length

10M

Power supply

AC85-265V AC50 / 60Hz 20VA

Body dimensions and weight

96 (W) × 208 (D) × 96 (H) mm 1.5kg

Probe dimensions

About Φ50 × 203mm

(Inner thread: 1-1 / 4-11-1 / 2NPT female thread)

* 1 At 20 ° C or higher, the upper limit of the measurement range is ~ 19.7mg / L at 20 ° C and ~ 9.9mg / L at 35 ° C.

* 2 DC0-1V, 1-5V can be selected at the time of shipment

Note) Specifications are subject to change without notice for product improvement.